The Schneider Electric Masterpact NW25H1, catalogue reference 48306, is a 2500 A, 4-pole, drawout air circuit breaker frame with a 65 kA breaking capacity (performance level H1), supplied without a trip unit. It is a low-voltage power circuit breaker to IEC 60947-2, suitable for isolation, and is used as a main incomer, bus-tie or sub-main device in large LV switchboards. The matching Micrologic control unit, chassis and rear connections are ordered separately to complete the ACB.
| Attribute | Value |
|---|---|
| Range | Schneider Electric Masterpact NW |
| Reference | 48306 (NW25H1) |
| Type | Air circuit breaker (ACB), drawout |
| Rated current (In) | 2500 A at 40 degrees C |
| Poles | 4-pole (4P) |
| Breaking capacity (Icu) | 65 kA at 440 V AC (performance level H1) |
| Short-time withstand (Icw) | 65 kA for 1 second |
| Rated voltage (Ue) | 690 V AC 50/60 Hz |
| Control unit | Not included, order Micrologic separately |
| Suitability for isolation | Yes, to EN/IEC 60947-2 |
| Standard | IEC 60947-2 |
| Weight | Approx 49.5 kg |
Reference 48306 is the breaker frame only. The following genuine Schneider parts complete a working 2500 A 4-pole drawout ACB, and we can supply them together as a matched set:
| Reference | Part | Role |
|---|---|---|
| 48306 | Basic breaker frame | NW25H1 2500 A 4-pole drawout frame (this product) |
| 48498 | Micrologic 2.0 E trip unit | Control unit with LI protection and energy metering |
| 48406 | Drawout chassis | NW 4-pole 2500 A chassis (cradle) for the drawout breaker |
| 48169 | Top rear connection | Horizontal rear connection, 4-pole 2500 A, top |
| 48174 | Bottom rear connection | Horizontal rear connection, 4-pole 2500 A, bottom |
The Masterpact NW25H1 is designed for the main and sub-main protection of large low-voltage distribution switchboards, typically as an incomer or bus-coupler at 2500 A. As a drawout device it racks into a fixed NW chassis, allowing safe isolation and removal for maintenance without disturbing the switchboard wiring.
Because this reference is drawout and without a control unit, confirm the chassis (48406), Micrologic unit (48498) and rear connections (48169 and 48174) before ordering. Our engineer can verify the full configuration against your existing switchboard.
No. Reference 48306 is supplied as a 4-pole drawout frame without a control (trip) unit. A Micrologic control unit must be ordered separately and matched to the protection functions your installation needs.
The 48306 is the bare breaker frame. To assemble a complete, working drawout ACB you also need the Micrologic 2.0 E trip unit (48498), the 4-pole 2500 A drawout chassis (48406), and the top and bottom horizontal rear connections (48169 and 48174). We can supply all of these genuine Schneider parts together so the breaker arrives ready to commission.
The NW25H1 has a rated ultimate breaking capacity (Icu) of 65 kA at 440 V AC, which corresponds to performance level H1, and a short-time withstand current (Icw) of 65 kA for 1 second, conforming to IEC 60947-2.
No. The Masterpact NW is a current Schneider Electric range and reference 48306 has not been replaced. The Masterpact MTZ is a separate newer generation and is not a drop-in replacement in an existing NW cradle, so NW switchboards continue to be extended and maintained with genuine NW breakers.
A drawout (withdrawable) breaker racks in and out of a fixed chassis, so it can be isolated and removed for maintenance without disturbing the busbar and cable connections. A fixed breaker is permanently connected. Reference 48306 is the drawout version and needs a matching NW chassis such as 48406.
It depends on the protection required: Micrologic 2.0 E (48498) provides overload and short-circuit (LI) protection with energy metering, 5.0 adds adjustable short-time (LSI), 6.0 adds earth-fault protection and 7.0 adds earth-leakage. Our engineer will match the correct Micrologic unit to your application.
| SKU | MAS0832348306 |
|---|---|
| Manufacturer | Schneider Electric |
| Weight (kg) | 49.501000 |
| Model Number | 48306 |
| Mounting Mode | Drawout |
| Number Of Poles | 4P |
| TYPE OF TRIP UNIT | Micrologic 2.0 |
| RATED AMPERE (A) | 2500 |
| Mode Of Control | Manually Operated (Non Motorised) |
| [Icw] Rated Short-Time Withstand Current | 65 kA 1 s conforming to IEC 60947-2 65 kA 3 s conforming to IEC 60947-2 |
| Electrical Durability | AC-3: 6000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 2500 cy |
| Mechanical Durability | 10000 cycles without maintenance conforming to IEC 60947-2 20000 cycles with maintenance conforming to IEC 60947-2 |
| Standard | IEC 60947-2 |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Neutral Position | Left |
| Rated Frequency | 50/60 Hz |
| Ambient Air Temperature for Operation | -25…70 °C |
| Network Type | AC |
| Mercury Free | Yes |
| Product Certification | ASTA |
| Warranty | 18 months |
| RoHS Exemption Information | YES |
| Circuit Breaker Type | Air Circuit Breakers |