Facebook Pixel
Schneider Electric A9F44202 Acti9 iC60N 2-pole 2A C-curve miniature circuit breaker

Schneider Electric A9F44202 Acti9 iC60N 2P 2A C-Curve MCB - 6kA (IEC/EN 60898-1)

Schneider Electric A9F44216 Acti9 iC60N 2-pole 16A C-curve miniature circuit breaker

Schneider Electric A9F44216 Acti9 iC60N 2P 16A C Miniature Circuit breaker

Schneider Electric A9F44206 Acti9 iC60N 2P 6A C Miniature Circuit breaker

was AED 95.00 Special Price AED 57.00

Supply Advantage

  • Genuine Schneider Electric Acti9 iC60N — original stock, not grey-market
  • Ready stock in Dubai & Mumbai — fast UAE / GCC dispatch & export
  • VAT invoice provided for business, panel-builder & project procurement
  • Engineer-checked technical support before dispatch
  • Request a quote for bulk / project quantities
Availability: In stock
SKU
MAS03417A9F44206
There are no file attachments for this product.

Have a question about this product?

The Schneider Electric Acti9 iC60N (A9F44206) is a 2-pole, 6A, C-curve miniature circuit breaker for short-circuit and overload protection in low-voltage distribution boards. It is dual-certified to IEC/EN 60898-1 and IEC/EN 60947-2, making it suitable for both residential-standard and industrial-standard installations across panel-builder, MEP and building-services work.

Quick Specifications

  • Brand and series — Schneider Electric Acti9 iC60N
  • Part number — A9F44206
  • Poles — 2P, with 2 protected poles
  • Rated current (In) — 6 A
  • Tripping curve — C, trips at 5 to 10 times rated current
  • Breaking capacity — 6,000 A (Icn) at 415 V AC per IEC/EN 60898-1, and up to 20 kA (Icu) at 220–240 V AC per IEC/EN 60947-2
  • Rated insulation voltage (Ui) — 500 V AC
  • Standards — IEC/EN 60898-1 and IEC/EN 60947-2
  • Mounting — 35 mm DIN rail, 36 mm wide (2 modules)
  • Protection degree — IP20, IP40 in enclosure
  • Operating temperature — -35 °C to +70 °C
  • Genuine Schneider stock with fast UAE and GCC dispatch, export supported

Applications & Compatibility

The iC60N 2P protects single-phase (line and neutral) or two-phase circuits, switching both poles together. The C curve suits general and mixed loads with moderate inrush — lighting circuits, socket outlets, small motors and control panels. It clips onto standard 35 mm DIN rail and works with the wider Acti9 accessory range, including auxiliary contacts, shunt trips and comb busbars.

  • Distribution boards for commercial, residential and light-industrial buildings
  • Control and automation panels built by MEP contractors and panel builders
  • Circuits requiring dual IEC 60898-1 and 60947-2 compliance

Why Buy From Electrical Junction

We are a Dubai-based distributor of genuine switchgear, backed by our own sourcing arm in Mumbai — not an anonymous marketplace. Every order below is handled by a real specialist.

  • Genuine original Schneider Electric Acti9, sourced through our Mumbai import arm (MAS Global Enterprises) — never grey-market.
  • Ready regional stock held in Dubai and Mumbai for fast UAE and GCC dispatch, with international export supported.
  • Technical and export queries handled directly by our engineer, so you can confirm compatibility and breaking capacity before you order.
  • VAT invoice provided, with project and bulk quantities quoted on request.

Frequently Asked Questions

What does the "C" curve mean on the A9F44206?

The C curve trips on short-circuit between 5 and 10 times the rated current, which is 30 to 60 A on this 6 A device. It suits general and mixed loads with moderate inrush, such as lighting and socket circuits. Choose a B curve for purely resistive or low-inrush loads, or a D curve for high-inrush loads like transformers and larger motors.

Is the iC60N breaking capacity 6 kA or 20 kA?

Both figures are correct under different standards. The iC60N is rated 6,000 A (6 kA) Icn at 415 V AC to IEC/EN 60898-1, and is additionally certified up to 20 kA Icu at 220–240 V AC to IEC/EN 60947-2. Use the figure that matches the standard your design references — for most building-services boards, the 6 kA IEC 60898-1 rating applies.

What is the difference between iC60N and iC60H?

The suffix indicates the breaking-capacity class. The iC60N is the 6 kA (60898-1) class, while the iC60H offers a higher 10 kA (60898-1) rating for boards with higher prospective fault levels. If your fault-level calculation exceeds 6 kA, specify the iC60H instead.

Does 2P mean it protects both line and neutral?

Yes. The 2P version has two protected poles that switch together, used for single-phase line-and-neutral circuits or two-phase circuits. Both poles are isolated simultaneously on trip or manual switch-off.

Do you deliver to Saudi Arabia and export outside the UAE?

Yes. We hold ready stock in Dubai and Mumbai and regularly supply across the GCC and for international export. Contact us with quantity and delivery location for a quote.

More Information
SKU MAS03417A9F44206
Weight (kg) 0.250000
Manufacturer Schneider Electric
Network Type AC
Number Of Poles 2P
Rated Short Circuit Capacity - KA 6KA
Standard EN/IEC 60947-2 EN/IEC 60898-1
Rated Frequency 50/60 Hz
Model Number A9F44206
RATED AMPERE (A) 6
Circuit Breaker Type Miniature Circuit Breakers
Write Your Own Review
You're reviewing:Schneider Electric A9F44206 Acti9 iC60N 2P 6A C Miniature Circuit breaker