The Schneider Electric A9N61537 is a 2-pole, 40 A, C-curve Acti9 C60H-DC miniature circuit breaker rated for 500 V DC circuits. It is a DC-dedicated device built to protect solar PV strings, battery banks, DC distribution and DC control circuits, where the fault arc behaves very differently from an AC circuit and demands a purpose-rated breaker. Both poles are connected in series to reach the full 500 V DC rating and to reliably extinguish the DC arc during a fault.
The 40 A C60H-DC suits main-circuit protection on the direct-current side of a system.
Electrical Junction is a Dubai-based distributor of genuine Schneider Electric, ABB and Lovato switchgear, sourced through our Mumbai arm (MAS Global Enterprises) across India, China and Europe. DC solar protection is a category we handle daily, so specification questions reach an engineer rather than a ticket queue.
Is the A9N61537 suitable for solar PV and DC circuits?
Yes. The A9N61537 is a DC-only miniature circuit breaker rated for 500 V DC and 40 A, purpose-built to protect solar PV strings, battery banks and DC distribution circuits. It is designed to safely break DC fault arcs, which behave very differently from AC arcs, so it must never be replaced with a standard AC MCB on the DC side of a system.
What is the breaking capacity of the A9N61537?
The A9N61537 has a rated ultimate breaking capacity (Icu) of 6 kA at 500 V DC, rising to 10 kA at 440 V DC and 20 kA at 220–250 V DC, all conforming to IEC/EN 60947-2. Listings that quote a single 20 kA figure are stating the value at the lower 220 V DC point only, not at the full 500 V DC operating voltage.
Why does a single DC line need a 2-pole breaker?
On the A9N61537 both poles are connected in series to reach the 500 V DC rating and to reliably extinguish the DC arc during a fault. Connection polarity is marked on the front of the device and must be observed, since a DC breaker only interrupts correctly when wired in the intended current direction.
Can I use a standard AC MCB instead on my solar strings?
No, and doing so is a genuine safety hazard. DC arcs do not self-extinguish at a zero-crossing the way AC arcs do, so an AC-rated MCB may fail to clear a DC fault and can overheat or catch fire. Always use a DC-rated device such as the C60H-DC on the DC side of a solar or battery system.
Do you stock the A9N61537 in Dubai and can you supply in bulk?
Yes. Electrical Junction stocks genuine Schneider Electric C60H-DC breakers at our Dubai counter for fast dispatch across the UAE and GCC, with walk-in collection available. For panel builders and solar EPC contractors we quote BOQ and bulk requirements the same day, with DC sizing checked by our engineer before dispatch.
| SKU | MAS03530A9N61537 |
|---|---|
| Weight (kg) | 0.256000 |
| Manufacturer | Schneider Electric |
| Network Type | AC/DC |
| Number Of Poles | 2P |
| Voltage (volt AC) | 500 V DC |
| Standard | EN 60947-2 |
| Rated Frequency | 50/60 Hz |
| Model Number | A9N61537 |
| Mechanical Durability | 20000 cycles |
| RATED AMPERE (A) | 40 |
| Electrical Durability | 3000 cycles 500 V DC |
| Circuit Breaker Type | Miniature Circuit Breakers |